1.       SAFETY INSTRUCTIONS:

1.1.     Instruction and trial-run must be done by professional technician;

1.2.     Pls ensure the grounded wire working well;

1.3.     Do not step on foot pedal when motor turns on;

1.4.     Control box and motor cover are forbidden to open when power turn-on;

1.5.     Pls Ensure power off during below operations:

a)  When threading,changing needle and inner stitching thread;

b)  When installing machine and maintaining;

c)  When turning over the machine.

2.       OPERATION PANEL INSTRUCTIONS:

2.1.     Each Key purpose:

KEY

SEWING MODEL

FUNCTION MODEL

P

Needle position choice

Confirm the operation,it will enter into setting model with other keys;

S

LED light on-off

Confirm the parameter setting.

+

Sewing speed-up

Key to add parameter and index.

-

Sewing slow-down

Key to reduce parameter and index.

 

 

2.2.                                      ADJUSTING TECHNICIAN MODEL PARAMETER:

a)       Press key”P”,meanwhile press key”+”once,the screen will show P-00;

b)       Press key”+”or”-”till the parameter model number required;

c)        Press key”p”into parameter,the screen will show the parameter;

d)       Press key”+”or”-”till the required parameter;

e)       Press key”S”to save parameter and quit.

2.3.                                      RESTORE FACTORY SETTING:

   Press key”P”,meanwhile press key”+”,the screen will show P-00;Then press key”S” 3 seconds,it will resource factory settings.

3.                                          TECHNICIAN MODEL PARAMETER DIAGRAM:

PARAMETER CODE

DESCRIPTION

ADJUSTING SCOPE

FACTORY SETTING

REMARK

P-01

Max speed

200-7000

4500

 

P-02

Direction of rotation

0: Reverse turn

1: Clockwise turn

1

 

P-03

The needle Angle

6-18

12

 

P-04

Sewing-begin speed

200-800rpm

250

 

P-05

Speed-up and slow-down

300-1200

850

 

P-06

Setting the seam

0-999needle

0

 

P-07

Reserve

 

 

 

P-08

Reserve

 

 

 

P-09

Reserve

 

 

 

P-10

Automatic clearance run

0: normal sewing

1: automatic clearance run

0

Turn off the power,running stop

P-11

Lift the press foot current

1000-3600

3000

Special for lifting and pressing feet of electromagnets

P-12

Lifting and pressing foot holding time

5-60

30

Special for lifting and pressing feet of electromagnets

   P-13

Reserve

 

0

 

P-14

Maximum current limit

50-500

350

 

P-15

The location of topper needle

0: No detecting

1: Detecting needle

1

 

P-16

The maximum speed of the motor is given

200-7000

3500

 

   P-17

Reserve

 

1

 

   P-18

password setting

 

2013

 

 

4.                                          FAULT SOLUTION:

ERROR CODE

CONTENT

REASON

Er01

No found needle position

The gap between handle wheel and motor cover is too big;

Nine plug connects not well;

Motor hall broken,it should change new motor;

The magnet in handle wheel is lost.

Er02

The speed regulator is not found when power-on

Speed regulator plug not plug-in or badly connected;

The speed regulator wire is broken.

Er03

Motor hall or phase error

Nine plug not connected wall;

Motor not installed well;

Hall broken.

Er04

Lock-rotor protection

Motor overloaded;

Motor is not well connected.

Er05

Hardware over-current protection

Motor overloaded;

Signal wire badly connected or broken.

Er07

Serial port communication timeout error

The wire between display and main board is not good or main board broken.

 