GBSM-34N Manual

Download file here
Energy-Efficient Motors User Manual
1. SAFETY INSTRUCTIONS:
1.1. Instruction and trial-run must be done by professional technician;
1.2. Pls ensure the grounded wire working well;
1.3. Do not step on foot pedal when motor turns on;
1.4. Control box and motor cover are forbidden to open when power turn-on;
1.5. Pls Ensure power off during below operations:
a) When threading,changing needle and inner stitching thread;
b) When installing machine and maintaining;
c) When turning over the machine.
2. OPERATION PANEL INSTRUCTIONS:
2.1. Each Key purpose:
KEY | SEWING MODEL | FUNCTION MODEL |
P | Needle position choice | Confirm the operation,it will enter into setting model with other keys; |
S | LED light on-off | Confirm the parameter setting. |
+ | Sewing speed-up | Key to add parameter and index. |
- | Sewing slow-down | Key to reduce parameter and index. |
2.2. ADJUSTING TECHNICIAN MODEL PARAMETER:
a) Press key”P”,meanwhile press key”+”once,the screen will show P-00;
b) Press key”+”or”-”till the parameter model number required;
c) Press key”p”into parameter,the screen will show the parameter;
d) Press key”+”or”-”till the required parameter;
e) Press key”S”to save parameter and quit.
2.3. RESTORE FACTORY SETTING:
Press key”P”,meanwhile press key”+”,the screen will show P-00;Then press key”S” 3 seconds,it will resource factory settings.
3. TECHNICIAN MODEL PARAMETER DIAGRAM:
PARAMETER CODE | DESCRIPTION | ADJUSTING SCOPE | FACTORY SETTING | REMARK |
P-01 | Max speed | 200-7000 | 4500 |
|
P-02 | Direction of rotation | 0: Reverse turn 1: Clockwise turn | 1 |
|
P-03 | The needle Angle | 6-18 | 12 |
|
P-04 | Sewing-begin speed | 200-800rpm | 250 |
|
P-05 | Speed-up and slow-down | 300-1200 | 850 |
|
P-06 | Setting the seam | 0-999needle | 0 |
|
P-07 | Reserve |
|
|
|
P-08 | Reserve |
|
|
|
P-09 | Reserve |
|
|
|
P-10 | Automatic clearance run | 0: normal sewing 1: automatic clearance run | 0 | Turn off the power,running stop |
P-11 | Lift the press foot current | 1000-3600 | 3000 | Special for lifting and pressing feet of electromagnets |
P-12 | Lifting and pressing foot holding time | 5-60 | 30 | Special for lifting and pressing feet of electromagnets |
P-13 | Reserve |
| 0 |
|
P-14 | Maximum current limit | 50-500 | 350 |
|
P-15 | The location of topper needle | 0: No detecting 1: Detecting needle | 1 |
|
P-16 | The maximum speed of the motor is given | 200-7000 | 3500 |
|
P-17 | Reserve |
| 1 |
|
P-18 | password setting |
| 2013 |
|
4. FAULT SOLUTION:
ERROR CODE | CONTENT | REASON |
Er01 | No found needle position | The gap between handle wheel and motor cover is too big; Nine plug connects not well; Motor hall broken,it should change new motor; The magnet in handle wheel is lost. |
Er02 | The speed regulator is not found when power-on | Speed regulator plug not plug-in or badly connected; The speed regulator wire is broken. |
Er03 | Motor hall or phase error | Nine plug not connected wall; Motor not installed well; Hall broken. |
Er04 | Lock-rotor protection | Motor overloaded; Motor is not well connected. |
Er05 | Hardware over-current protection | Motor overloaded; Signal wire badly connected or broken. |
Er07 | Serial port communication timeout error | The wire between display and main board is not good or main board broken. |